Equipment Signs
Fire safety signs are used to provide health and safety information, highlight key locations and provide advice and instructions. In the case of fire equipment signs, they are required above fire equipment to clearly identify the location of the appropriate equipment (such as fire blankets) which in turn enables viewers to locate it quickly and easily. Additionally, other fire equipment signs can be located above the equipment to provide advice regarding inspection date etc.
Under the Regulatory Reform - Fire Safety Order 2005 any non-automatic fire fighting equipment should be identified with an appropriate sign. The signs should be positioned and designed in accordance with BS EN ISO 722 to ensure maximum levels of comprehension.
Fire Hose Keep Clear
This "Fire Hose Keep Clear" safety sign is essential for maintaining unobstructed access to fire hos..
Fire Point
"Fire Point" safety signs are crucial for clearly identifying designated areas where fire safety equ..
Fire Point Number
A Fire Point Number sign is important for clearly identifying specific fire safety equipment locatio..
Fire Point Arrow Left Location
This Fire Point sign is essential for guiding people quickly and efficiently to the nearest fire poi..
Fire Point Arrow Right Location
This Fire Point sign is crucial for quickly and clearly directing people to the nearest fire point, ..
Fire Fighting Equipment
A Fire Fighting Equipment sign is crucial for clearly indicating the location of essential fire safe..
Fire Emergency Telephone
A Fire Emergency Telephone Safety Sign plays a vital role in emergency preparedness by clearly marki..
Manual Fire Hose Reel with Instructions for Use
An essential part of fire safety systems in buildings and facilities. It clearly identifies the loca..
Automatic Fire Hose Reel with Instructions for Use
A critical safety feature in buildings equipped with fire protection systems. Unlike manual reels, a..
Co2 Release Manual Control Point
A CO₂ Release Manual Control Point is a critical component of a fire suppression system, specificall..
Fire Blanket Identification
A Fire Blanket Identification Sign is important because it clearly marks the location of a fire blan..
Hose Reel Identification
This fire safety sign enables viewers to locate a fire hose quickly and easily. Under the Regulatory..
Directional Indicator for Fire Equipment
Supplementary directional indicators may be used in combination with fire equipment safety signs to ..
Dry Riser Outlet
Under the Regulatory Reform (Fire Safety) Order 2005 any non-automatic fire fighting equipment shoul..
Dry Riser Inlet
Under the Regulatory Reform (Fire Safety) Order 2005 any non-automatic fire fighting equipment shoul..
Fire Safety Log Book Holder (empty)
This wall mounted station ensures that the fire log book (not included - please order separately) is..
Fire Point - Projecting Sign
Use projecting signs to identify the location of fire equipment from several view points Face: 150 x..
Fire Fighting Equipment - Projecting Sign
Use EasiFIX projecting signs to identify the location of fire equipment from several view points Fac..
Black Cut Out Numbers 25mm Cap Height
Sheet of 1 Character height - 25mm Miscellaneous Products / MaterialsAny product outside of our sta..
White Cut Out Numbers
Sheet of 1 Character height - 25mm Miscellaneous Products / MaterialsAny product outside of our s..
Fire Blanket
Under the Regulatory Reform (Fire Safety Order 2005 any non-automatic fire fighting equipment should..
Open Valve Before Running Out Hose
Under the Regulatory Reform (Fire Safety Order 2005 any non-automatic fire fighting equipment should..
Fire Hose Symbol
Under the Regulatory Reform (Fire Safety Order 2005 any non-automatic fire fighting equipment should..
Fire Fighter's Switch
Under the Regulatory Reform (Fire Safety Order 2005 any non-automatic fire fighting equipment should..
Fire Hose
Under the Regulatory Reform (Fire Safety Order 2005 any non-automatic fire fighting equipment should..
Fire Point
Under the Regulatory Reform (Fire Safety Order 2005 any non-automatic fire fighting equipment should..
Fire Bucket
Under the Regulatory Reform (Fire Safety Order 2005 any non-automatic fire fighting equipment should..
Dry Riser
Under the Regulatory Reform (Fire Safety Order 2005 any non-automatic fire fighting equipment should..
Wet Riser
Under the Regulatory Reform (Fire Safety Order 2005 any non-automatic fire fighting equipment should..
Hydrant Marker
Under the Regulatory Reform (Fire Safety Order 2005 any non-automatic fire fighting equipment should..
Hose Reel Identification Sign
Under the Regulatory Reform (Fire Safety Order 2005 any non-automatic fire fighting equipment should..
Fire Blanket Identification
Under the Regulatory Reform (Fire Safety Order 2005 any non-automatic fire fighting equipment should..
Sprinkler Stop Valve Inside
Sprinklers are seen as the only system which detects a fire, suppresses a fire and raises the alarm,..
Sprinkler Stop Valve
Sprinklers are seen as the only system which detects a fire, suppresses a fire and raises the alarm,..
Sprinkler Control Valve
Sprinklers are seen as the only system which detects a fire, suppresses a fire and raises the alarm,..
This Valve Controls Automatic Sprinkler System and must Always be Kept Open
Sprinklers are seen as the only system which detects a fire, suppresses a fire and raises the alarm,..
Hydraulic Sprinkler System ID Plate Sign
Sprinklers are seen as the only system which detects a fire, suppresses a fire and raises the alarm,..
Do Not Hang Items from Fire Sprinkler
Sprinklers are seen as the only system which detects a fire, suppresses a fire and raises the alarm,..
Fire Safety - Document Holder
This sign enables you to keep important fire safety documents in a safe central clearly displayed ce..
EasiFix Fire Action - in the event of a Fire - Lift the Cover and Activate Alarm
BS 5839-1: 2007 Fire Detection and Fire Alarm Systems in Buildings recommend that manual call points..
Hydrant Marker Kit 180 x 205mm
Manufactured to BS3251 from exceptionally durable, non-fade injection moulded plastic. Information i..
AOV Control Box
AOV is an acronym for 'Automatic Opening Vent'. An AOV is a smoke ventilation system designed to ena..
AOV Switch Inside
AOV is an acronym for 'Automatic Opening Vent'. An AOV is a smoke ventilation system designed to ena..
Automatic Opening Smoke Vent - Do Not Obstruct
AOV is an acronym for 'Automatic Opening Vent'. An AOV is a smoke ventilation system designed to ena..
Smoke Vent - Control Box
AOV is an acronym for 'Automatic Opening Vent'. An AOV is a smoke ventilation system designed to ena..
Smoke Vent
AOV is an acronym for 'Automatic Opening Vent'. An AOV is a smoke ventilation system designed to ena..
Smoke Vent - Manual Control
AOV is an acronym for 'Automatic Opening Vent'. An AOV is a smoke ventilation system designed to ena..
Automatic smoke Vent - Keep Clear
AOV is an acronym for 'Automatic Opening Vent'. An AOV is a smoke ventilation system designed to ena..
Automatic Smoke Vent - Keep Clear of Obstructions
AOV is an acronym for 'Automatic Opening Vent'. An AOV is a smoke ventilation system designed to ena..